A pipe cover is an included component of T4 and T9 showers that feature the integral ILTDU, In-Line Thermal Disinfection Unit. In the case of -A- type shower panels, if it is preferred that the exposed pipe work be hidden, an optional pipe cover in the same profile as the shower panel can be fitted.
Pipe covers are available in two lengths: 465mm and 940mm and can be cut to size to fit your installation. To install the pipe cover, do not fit the shower panel's top end cap (not included with T4 or T9 type panels). Instead fit the (width brace), gasket and alignment pins. Cut the pipe cover to the appropriate length (see adjacent instructions) then slide the cover down to join with the panel, engaging with the alignment pins and the gasket. Take the cuff with its hole in the lower position and cover the gap between the pipe cover and the ceiling. Mark the position of the hole on the pipe cover. Drill a hole in the pipe cover then reposition it over the panel. Line up the holes on the pipe cover and cuff to mark the hole position on the wall. Drill the hole in the wall then secure the pipe cover into place, taking care not to excessively tighten the screw.
Useful part numbers:
SA-465PC - Standard pipe cover for -A type shower panels, 465mm.
SA-940PC - Standard pipe cover for -A type shower panels, 940mm.
SA-465T - (Replacement) adapted pipe cover (with ILTDU key slot) for T4 shower panels.
SA-940T - (Replacement) adapted pipe cover (with ILTDU key slot) for T9 shower panels.