Valve Sizing Tool

Setting the Temperature

Remove the tap's bottom cover cap and insert a 4mm hex key into the slot on the thermostatic cartridge cover.  Rotate clockwise to reduce the mixed water temperature and anti-clockwise to increase the mixed water temperature. Use a digital thermometer with immersion probe to measure the water temperature at the outlet.